MilliporeAervent CTGR Cartridge Filter 10 in. 0.2 µm Code 7 CTGR71TP1 NEW
$ 200.11
- Description
- Size Guide
Description
Millipore Aervent CTGR Cartridge Filter 10 in. 0.2 µm Code 7 CTGR71TP1 NEW. Unused. Surplus Inventory. Double Bagged. Selling AS-IS. No returns accepted!Overview
Description
Product Information
Biological Information
Physicochemical Information
Dimensions
Materials Information
Packaging Information
Description
Catalogue Number
CTGR71TP1
Trade Name
Aervent
®
Description
Aervent CTGR Cartridge Filter 10 in. 0.2 µm Code 7
Product Information
Device Configuration
Cartridge
Maximum Differential Pressure, bar (psid)
Forward: 5.5 bar (80 psid) @ 25 °C; 1.8 bar (25 psid) @ 80 °C. Reverse: 4.1 bar (60 psid), intermittent
Maximum Inlet Pressure, bar (psi)
Forward - 5.5 bar (80 psi) @ 25 °C; 1.7 bar (25 psi) @ 80 °C; Reverse - 4.1 bar (60 psi), Intermittent
Cartridge Code
Code 7
Quality Level
MQ400
Biological Information
Media
Aervent
®
Sterilization
150 (100 forward/50 reverse) SIP cycles of 30 min @ 145 °C
Bacterial Grow-Through
Retains
Brevundimonas diminuta
liquid aerosol for 21 days at a minimum challenge of 10⁷ CFU/cm²
Bacterial Retention
Samples were quantitatively retentive of a minimum
Brevundimonas diminuta
challenge concentration of 1 x 10⁷ CFU/cm² using ASTM
®
F838 methodology.
Wettability
Hydrophobic
Physicochemical Information
Pore Size
0.2 µm
Bubble Point at 23 °C
≥1100 mbar (16 psig) nitrogen with 70/30 % IPA/water
Gravimetric Extractables
The extractables level was equal to or less than 35 mg per 10-inch cartridge after 24 hours in a 70/30% IPA/water mixture at controlled room temperature.
HydroCorr
≤0.75 mL/min @ 2.6 bar (38 psig) per 10 in cartridge
Nitrogen Diffusion at 23 °C
≤24 mL/min @ 970 mbar (14 psig) in 70/30 % IPA/water
Non-Fiber Releasing
This product was manufactured with a PTFE membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
Virus Aerosol Retention
Rated for aerosol retention of a total challenge of 108–1010 plaque forming units of ΦX-174 virus particles at 85 Nm3/h (50 SCFM) per cartridge.
USP Bacterial Endotoxins
Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Dimensions
Cartridge Nominal Length
10 in. (25 cm)
Diameter
6.9 cm (2.7 in.)
Filtration Area
0.65 m²
Device Size
10 in.
Materials Information
Chemistry
Polytetrafluoroethylene (PTFE)
Device Material
Polypropylene
Seal Material
Silicone (SI)
Support Material
Polypropylene
Packaging Information
Material Size
1
Material Package
Double Easy-Open bag